Place of Origin: | BEIJING,CHINA |
---|---|
Brand Name: | GFUVE |
Model Number: | GF302D1 |
Minimum Order Quantity: | 3 SETS |
Packaging Details: | CARTON |
Delivery Time: | 1-2WEEKS |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 1500SETS/MONTH |
ACCURACY: | 0.05%, 0.1% | Power Supply: | One Phase AC 100-265V, Frequency 50/60Hz. |
---|---|---|---|
VOLTAGE RANGE: | 57.7V, 100V, 220V, 380V Or 69.3V, 120V, 240V, 480V( Optional) | Harmonic: | 2-51times |
Frequency: | 40Hz-70Hz | Dimension: | 495x390x195mm |
Weight: | 15kg | ||
High Light: | Kwh Meter Calibration Equipment,40Hz Meter Calibration Equipment,TFT Touch Screen Meter Calibration Equipment |
Kwh Three Phase Meter Calibration Tester,High Accuracy,Extra Cirecuit Protection,Stable Power Output
INTRODUCTION
The GF302D1 portable test system consists of an integrated three-phase current source and a three-phase electronic reference standard of accuracy class 0.05. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment allows the monitoring of meter installations as well as analysis of the local mains conditions.
FEATURES
PARAMETERS
Accuracy class | 0.05%, 0.1% |
Power supply | One Phase AC 100-265V, frequency 50/60Hz. |
AC Voltage output | |
---|---|
Range(U1,U2,U3) | 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) |
Adjustment range | (0-120)%RG(1) |
Adjust fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.3% (Non-capacitive load) |
Output load | each phase 30VA |
Measuring accuracy | 0.05%RG |
AC Current output | |
Range (I1, I2, I3 ) | 200mA, 1A, 5A, 20A, 100A(optional) |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.3% (Non-capacitive load) |
Output load | 30VA |
Accuracy | 0.05%RG |
Power output | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.05%RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.03° |
Power Factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 10, 1, 0.1, 0.01 as optional. |
Measurement accuracy | 0. 0005 |
Frequency Output | |
Adjustment range | 40Hz-70Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Voltage /Current/Harmonic Setting | |
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error | |
Active power energy | 0.05%RG |
Reactive power energy | 0.1%RG |
Power Pulse Output | |
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V,10mA |
Power Pulse Input | |
Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 495x390x195 |
Weight (kg) | 15 |
Environmental conditions | |
Ambient temperature | -10°C to +50°C |
Relative humidity | 35%-85% |