Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
More information facilitates better communication.
Submitted successfully!
We will call you back soon!
Leave a Message
We will call you back soon!
Your message must be between 20-3,000 characters!
Please check your E-mail!
| Place of Origin: | BEIJING CHINA |
|---|---|
| Brand Name: | GFUVE |
| Certification: | CNAS CE ISO9001 |
| Model Number: | GF6019 0.05% |
| Minimum Order Quantity: | 1set |
| Packaging Details: | standard export wooden box |
| Delivery Time: | 10days |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability: | 200sets/month |
| PRODUCT NAME: | Portable DC Voltage Source And Current Source | APPLICATION: | Testing DC Meter |
|---|---|---|---|
| Current Range: | 0-500a | Voltage Range: | 0-1000v |
| Accuracy: | 0.05%, 0.02% | Function: | Testing Of DC Power Meter, Ammeter, Voltmeter |
| Stability: | 0.01%/1min | Usage: | Laboratory |
| High Light: | 1000V 500A Electrical Test Equipment,500A 1000V Electrical Test Equipment |
||
GF6019 1000V 500A Portable DC voltage source and current source of testing DC meter with electric power calibrator
| Electrical parameters | |
|---|---|
| Accuracy | 0.05% |
| Power Supply | One Phase AC 180-265V, frequency 50/60Hz. |
| DC Voltage Output | |
| Range | 65V, 250V, 500V, 750V, 1000V (max 1150V) |
| Adjustment range | (0-120)%RG(1) |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | 0.01%/120s |
| Distortion | 0.1% (Non-capacitive load) |
| Output load | 50VA |
| Full load regulation rate | ≤±0.01%RG |
| Accuracy | ±(0.03%RD+0.02%RG) |
| DC Current Output | |
| Range | 0.001A, 0.005A, 0.02A, 0.05A, 0.2A, 1A, 3A, 10A, 20A, 50A, 100A, 500A (max 600A) small signal 2.5mV, 20mV, 100mV, 1V, 5V |
| Adjustment range | (0-120)%RG |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | <0.01%/120s, small signal 2uV/min |
| Distortion | ≤0.1% (Non-capacitive load) |
| Output load | 1200VA |
| Full load regulation rate | ≤±0.01%RG |
| Accuracy | ±(0.03%RD+0.02%RG) |
| Externally attached shunt | 100mV |
| Accuracy | ±(0.06%RD+0.04%RG) |
| DC Power Output | |
| power output stability | <0.01%RG/120s |
| power accuracy | ±(0.03%RD+0.02%RG) |
| DC Power Energy Measurement Error | |
| power energy | ±(0.03%RD+0.02%RG) |
| Power Pulse Output | |
| Power Pulse Output | 20KHz (Full-Range) |
| Power Pulse Input | |
| Energy pulse input | 20KHz |
| Ripple output | 20-500Hz ripple output |
| Communication port | USB port, RS232, 10/100M LAN |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 630x600x450 |
| Weight (kg) | 20,55 |
| Environmental conditions | |
| Ambient temperature | -10°C to +40°C |
| Relative humidity | -30°C to 60°C |
| (1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
|
PHOTO
