                    Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
| Place of Origin: | CHINA | 
|---|---|
| Brand Name: | GFUVE | 
| Certification: | CE IEC ISO | 
| Model Number: | GF106 | 
| Minimum Order Quantity: | 1 Set | 
| Price: | Negotiable | 
| Packaging Details: | Aluminium Case | 
| Delivery Time: | 3-4 Weeks | 
| Payment Terms: | T/T, D/P, Western Union, MoneyGram, L/C | 
| Supply Ability: | 200Sets/Month | 
| Name: | CT PT Analyzer | Accuracy Class: | 0.1 0.05 | 
|---|---|---|---|
| Excitation Output Voltage: | 0-220Vrms | Excitation Output Current: | 0-5Arms (20A Peak-value) | 
| Automatic Frequency Variation Range: | 0.1-60Hz | Weight (kg): | 10KG | 
| Highlight: | circuit breaker analyzer,power transformer testing equipment | ||
| I. Current Transformer (CT) | II. Voltage Transformer (PT) | 
|---|---|
| 1. Magnetization curve | 1. Excitation characteristic test | 
| 2. Transformation ratio test | 2. Transformation ratio test | 
| 3. Polarity | 3. Polarity | 
| 4. 5% and 10% error curve | 4. Ratio error, phases | 
| 5. Current Injecting | 5. Degauss | 
| 6. Degauss | 6. Calculation of knee point value | 
| 7. Ratio error, phases | 7. Actual secondary load (burden), test (burden) | 
| 8. Automatic calculation of excitation knee point value | 8. Resistance test | 
| 9. Actual secondary load test (burden) (load test) | |
| 10. Resistance test | |
| 11. Secondary winding time constant (Ts) | |
| 12. Remanence coefficient (Kr) | |
| 13. Transient dimensioning factor (Ktd) | |
| 14. Peak instantaneous error (Er) | |
| 15. Magnetizing inductance (LU) | |
| Electrical parameters | ||
|---|---|---|
| Accuracy | 0.05%, 0.1% | |
| Power supply | AC 220V±10% or AC 110V±10%, 50/60Hz | |
| Excitation output voltage | 0-220Vrms | |
| Excitation output current | 0-5Arms (20A peak-value) | |
| Automatic frequency variation range | 0.1-60Hz | |
| Equivalent excitation voltage | ≤5000V | |
| Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
| Secondary winding DC resistance measurement | Range | 0.1-300Ω | 
| Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
| Secondary actual load measurement | Range | 5VA-1000VA | 
| Accuracy | ≤0.5% (0.2%RD+0.3%RG)±0.1VA | |
| CT/PT phase error measurement | Accuracy | ±4min | 
| Resolution | 0.01min | |
| CT ratio error measurement | Range | 1-30000 | 
| Accuracy | ≤0.5% | |
| PT ratio error measurement | Range | 1-10000 | 
| Accuracy | ≤0.5% | |
| Standards | ||
| Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2-2012 | |
| Safety standards | GB 4793.1-2007 | |
| EMC | EMC standard 89/336/EEC | |
| FCC Subpart B of Part 15 Class A | ||
| IEC 1000-4-2/3/4/6 | ||
| Mechanical parameters | ||
| Overall dimension (L x W x H) (mm) | 410 x 250 x 300 | |
| Weight (kg) | ≤10 | |
| Environmental conditions | ||
| Relative humidity | 90RH% | |
| Operating temperature | -10°C to +40°C | |
| Altitude | ≤2000m | |
| The test items mainly include | |
|---|---|
| Steady | Transient | 
| excitation characteristic | secondary winding time constant (Ts) | 
| transformation ratio | remanence coefficient (Kr) | 
| polarity | transient dimensioning factor (Ktd) | 
| ratio error | peak instantaneous error (Er) | 
| phases | magnetizing inductance (LU) | 
| 5% and 10% error curves | other parameters | 
| resistance | |
| secondary load | |