Place of Origin: | BEIJING CHINA |
---|---|
Brand Name: | GFUVE |
Certification: | CNAS CE |
Model Number: | GF1061 PT |
Minimum Order Quantity: | 1set |
Packaging Details: | standard export wooden box |
Delivery Time: | 1-2weeks |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 200sets/month |
NAME: | High Voltage Potential Transformer Analyzer | Accuracy: | 0.05% |
---|---|---|---|
Ratio: | 0.8-30000 | Phase Error: | 2 Min |
Resistance: | 0.1-1000Ω | Reference Standards: | IEC60044-1, IEC60044-6, IEC61869, ANSI/IEEE C57.13 |
Keyword: | PT Analyzer | Weight: | 5KG |
LCD Display: | 7' Inch TFT Touch Color LCD | Knee Point Voltage: | 80KV |
High Light: | Smart Pt Potential Transformer,Automatic Pt Potential Transformer,IEC60044-1 Pt Potential Transformer |
GF1061PT Automatic Smart Medium voltage and high voltage potential transformer analyzer from 0.8 to 30000 ratio & 2 min error
GF1061PT is the first portable device (4.8 kg) which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration. It performs quick tests of all kinds of inductive voltage transformers (VTs or PTs) and capacitive voltage transformers (CVTs) for both protection and metering purposes. Its lightweight design makes it ideal for on-site tests and calibration tasks in power system grids.
As a manufacturer or testing lab you can use GF1061PT in your production facilities and test/development labs. it can finish the measurements (M) and protection (P) class PT. Adopt 7 inch touch TFT color LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The GF1061PT portable PT tester is the most complete and easy-to-use testing system for PTs according to IEEE and IEC standards.
I. Voltage transformer (PT) |
---|
1. Excitation characteristic test |
2. Transformation ratio test |
3. Polarity |
4. Ratio error, phase error |
5. Degauss |
6. Calculation of knee point value |
7. Actual secondary load test (burden test) |
8. Resistance test |
Electrical parameters | ||
---|---|---|
Accuracy | 0.02% | |
Power supply | AC 220V±10% or AC 120V±10%, 50/60Hz or Battery | |
Output voltage | 0-100Vrms | |
Output current | 0-5Arms (20A peak-value) | |
Output power | 0-400 VA (1500 VApeak) | |
Automatic frequency variation range | 0.1-60Hz | |
Equivalent excitation voltage | ≤5000V/50KV | |
Accuracy | ≤0.5% | |
Secondary winding DC resistance measurement | Range | 0.1-1000Ω |
Accuracy | ≤0.05% | |
Secondary actual load measurement | Range | 5VA-1000VA |
Accuracy | ≤0.5%±0.1VA | |
PT phase error measurement | Accuracy | ±1min (typical) / 3 min (guaranteed) |
Resolution | 0.1min | |
PT ratio error measurement | Range | 1-15000 |
Accuracy | ≤0.05% | |
LCD display | 7' inch TFT touch color LCD | |
Communication port | USB port | |
Printer | Yes, Thermal printer | |
Standards | ||
Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869, ANSI/IEEE C57.13 |
|
Safety standards | GB 4793.1-2007 | |
EMC | EMC standard 89/336/EEC | |
FCC Subpart B of Part 15 Class A | ||
IEC 1000-4-2/3/4/6 | ||
Mechanical parameters | ||
Overall dimension (L x W x H) (mm) | 280 x 250 x 160 | |
Weight (kg) | ≤4.8 | |
Environmental conditions | ||
Relative humidity | Relative humidity 5%-95% not condensing | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -20°C to +70°C | |
Altitude | ≤1000m |