Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
| Place of Origin: | BEIJING CHINA |
|---|---|
| Brand Name: | GFUVE |
| Certification: | CNAS, CE, ISO9001 |
| Model Number: | TEST-630 6U6I |
| Minimum Order Quantity: | 1SET |
| Packaging Details: | STANDARD EXPORT WOODEN BOX |
| Delivery Time: | 5-8DAYS |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability: | 200SETS/MONTH |
| PRODUCT NAME: | 3 Phase Portable Protection Relay Test Set Equipment | ACCURACY: | 0.05% |
|---|---|---|---|
| Application: | RELAY TEST AND PROTECTION DEVICE TEST | FUNCTION1: | Differential Relay Test |
| FUNCTION2: | Distance Protection | U/I RANGE: | 0-35A/0-300V AC/DC |
| LCD: | TFT COLOR LCD | WEIGHT: | 16.6KG |
| Highlight: | harmonics output relay test equipment,0.05% accuracy relay test equipment,TFT LCD relay test equipment |
||
TEST-630 smart automatic 3 phase portable protection relay test set equipment with harmonics output
| Electrical parameters | |
|---|---|
| Power voltage | AC220V±10% or AC110V±10%, 50/60Hz±10% |
| Time measurement | 0.1ms-999999.999s |
| AC current output | |
| Phase current output (effective value) | 3 x 0-30A |
| Maximum power output | 260VA/phase |
| Maximum parallel current output (effective value) | 0-90A |
| Long-term allowable working value of phase current (effective value) |
>10A |
| Allowable working time of maximum current | >11s |
| Accuracy class | <±0.2% |
| AC voltage output | |
| Phase voltage output (effective value) | 5 x 0-130V |
| Line voltage output (effective value) | 0-260V |
| Maximum power output | 70VA/phase |
| Accuracy class | <±0.2% |
| DC current output | |
| Output range | -10 to 10A or 3 x 0 to ±10A |
| Maximum power output | 200VA |
| Accuracy class | <±0.2% |
| DC voltage output | |
| Output range | 0-300V or 5 x 0 to ±130V |
| Maximum output power | 130VA |
| Accuracy class | <±0.2% |
| Binary input | |
| Idle contact | 1-20mA, 24V (DC) |
| Electric potential contact | 250V/0.5A (DC) |
| Binary output | |
| Idle contact | 250V/0.5A (DC) |
| Rated output | |
| Frequency error | <±0.01Hz |
| Phase error | <±0.2° |
| Waveform distortion | <±0.3% (fundamental wave) |
| Time error | <40µs |
| Output frequency | 0-1050Hz |
| Superposed harmonic wave | 0-21times |